Summary
Background/Aim: A factor affecting the success rate of dental implants, which has been used successfully for many years, is the implant-abutment connection system. The purpose of this study was to evaluate the stress distribution of different implant-abutment connection systems under different forces. Material and Methods: This in vitro study included a finite element analysis. In the study, the cylindrical and screwed dental implants available in 3 different diameters from 4 different companies were categorized into 12 different models. Two different scenarios of force application were conducted on each model in this study. In the first scenario, 100 N force and 100 N moment were applied in a vertical direction onto a point considered as the center of each tooth. In the second scenario, a 100 N force and moment were applied at a 45˚ angle in an oblique direction. Results: As a result of the forces applied to dental implants of different diameters from different companies, octagon implant-abutment connection systems had less stress accumulation than hexagon implant-abutment connection systems. In addition, when stress accumulation ratios were evaluated according to the diameter of the implants used, it was observed that 3 mm diameter implants accumulated more stress in bone than 4 mm diameter implants; there was no significant difference between 4 mm diameter implants and 5 mm diameter implants. Conclusions: Implant-abutment connection system is important for the longevity of implants under the forces. Therefore, this factor should be considered during implant selection.
Keywords: dental implant; stress distribution; finite element analysis; implant-abutment connection
Reference
Adell, R., Eriksson, B., Lekholm, U., Brånemark, P.I., Jemt, T. (1990) Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants, 5(4): 347-59
Akça, K., Çehreli, M.C., İplikçioğlu, H. (2002) A comparison of three-dimensional finite element stress analysis with in vitro strain gauge measurements on dental implants. Int J Prosthodont, 15:115-121
Akça, K., İplikçioğlu, H. (2001) Finite element stress analysis of the influence of staggered versus straight placement of dental implants. Int J Oral Maxillofac Implants, 16: 722-730
Balik, A., Karatas, M.O., Keskin, H. (2012) Effects of different abutment connection designs on the stress distribution around five different implants: A 3-dimensional finite element analysis. J Oral Implantol, 38:491-496
Bidez, M.W., Misch, C.E. (1992) Issues in bone mechanics related to oral implants. Implant Dentistry, 1(4): 289-294
Branemark, P.I., Zarb, G.A., Albrektsson, T. (1985) Tissue-integrated prostheses: Osseointegration in clinical dentistry. Chicago: Qiuntessence, 54:611-612
Branemark, P.I., Breine, U., Adell, R., Hansson, B.O., Lindström, J., Olsson, A. (1969) Intraosseous anchorage of dental prostheses: I: Experimental studies. Scand J Plast Recons Surg, 3:81-100
Branemark, P.I., Hansson, B.O., Adell, R., Breine, U., Lindström, J., Hallen, O., Ohman, A. (1977) Osseointegrated implants in the treatment of the edentulous jaw: Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl, 16: 1-132
Finger, I.M., Castellon, P., Block, M., Elian, N. (2003) The evolution of external and internal implant/abutment connections. Pract Proced Aesthet Dent, 15: 625-632
Kwon, J., Han, C., Kim, S., Chang, J. (2009) The change of rotational freedom following different insertion torques in three implant systems with implant driver. Journal of Advanced Prosthodontics, 1(1): 37-40
Marcián, P., Wolff, J., Horáčková, L., Kaiser, J., Zikmund, T., Borák, L. (2018) Micro finite element analysis of dental implants under different loading conditions. Computers in Biology and Medicine, 96: 157-165
Matsushita, Y., Kitoh, M., Mizuta, K., Ikeda, H., Suetsugu, T. (1990) Two-dimensional FEM analysis of hydroxyapatite implants: Diameter effects on stress distribution. J Oral Implantol, 16: 6-11
o’Mahony Aisling, M., Williams, J.L., Katz, J.O., Spencer, P. (2000) Anisotropic elastic properties of cancellous bone from a human edentulous mandible. Clinical Oral Implants Research, 11(5): 415-421
Perriard, J., Wiskott, W. A., Mellal, A., Scherrer, S.S., Botsis, J., Belser, U.C. (2002) Fatigue resistance of ITI implant-abutment connectors: A comparison of the standard cone with a novel internally keyed design. Clinical Oral Implants Research, 13(5): 542-549
Peyton, F.A., Craig, R.G. (1963) Current evaluation of plastics in crown and bridge prosthesis. Journal of Prosthetic Dentistry, 13(4): 743-753
Raoofi, S., Khademi, M., Amid, R., Kadkhodazadeh, M., Movahhedi, M.R. (2013) Comparison of the effect of three abutment-implant connections on stress distribution at the internal surface of dental implants: A finite element analysis. J Dent Res Dent Clin Dent Prospect, 7:132-139
van Zyl, P.P., Grundling, N.L., Jooste, C.H., Terblanche, E. (1995) Three dimensional finite element model of a human mandible incorporating six osseointegrated implants for stress analysis of mandibular cantilever prosthesis. Int J Oral Maxillofac Implants, 10: 51-57
Zarb, G.A., Alberktsson, T. (1991) Osseointegration: A requiem for the periodontal ligament?. Int J Periodontol Restor Dent, 11, str. 88-91
Balkan Journal of Dental Medicine, 2019, vol. 23, br. 3, str. 126-131